  1. FAP34070- RECONDITIONED

    FAP34070- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 70 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE MAY NOT ACCURATELY REPRESENT THE PRODUCT
    • ManufacturerSquare D Company
    • SeriesFAP
    • Phase3
    • Poles3
    • Voltage480
    • Amps70
  2. FAP26100- RECONDITIONED

    FAP26100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL LOAD LUG; SIZE 3 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY
    • ManufacturerSquare D Company
    • SeriesFAP
    • Phase3
    • Poles3
    • Voltage600
    • Amps100
  3. FAP34100- RECONDITIONED

    FAP34100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE MAY NOT ACCURATELY REPRESENT THE PRODUCT
    • ManufacturerSquare D Company
    • Series FAP
    • Phase3
    • Poles3
    • Voltage480
    • Amps100
  4. FHP36100- RECONDITIONED

    FHP36100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 25 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 18 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 50 KILOAMPERE AT 250 VDC; TERMINAL LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FH MODEL; APPLICABLE STANDARD W-C-375B/GEN; HIGH INTERRUPTING *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesFHP
    • Phase3
    • Poles3
    • Voltage600
    • Amps100
  5. FHP36070- RECONDITIONED

    FHP36070- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 70 AMPERE; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 25 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 18 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 50 KILOAMPERE AT 250 VDC; TERMINAL LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FH MODEL; APPLICABLE STANDARD W-C-375B/GEN; HIGH INTERRUPTING *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesFHP
    • Phase3
    • Poles3
    • Voltage600
    • Amps70
  6. FH36100- RECONDITIONED

    FH36100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 25 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 18 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 50 KILOAMPERE AT 250 VDC; TERMINAL PLUG ON; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FH MODEL; APPLICABLE STANDARD W-C-375B/GEN; HIGH INTERRUPTING *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesI-Line
    • Phase3
    • Poles3
    • Voltage600
    • Amps100
  7. FA32100- RECONDITIONED

    FA32100- RECONDITIONED

    240 VAC AT 50/60 HZ; 100 AMPERE; 3; 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 900 TO 1700 AMPERE; POWER DISTRIBUTION; CLASS 650/651 I-LINE[R] PANELBOARD/SWITCHBOARD; UL, CSA; FA; FA MODEL; FRAME TYPE F; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; TRIPPING METHOD THERMAL MAGNETIC; TERMINAL WIRE SIZE 14 TO 4 AWG (COPPER) *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesI-Line
    • Phase3
    • Poles3
    • Voltage240
    • Amps100
  8. FAB36100- RECONDITIONED

    FAB36100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL BOLT ON; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesI-Line
    • Phase3
    • Poles3
    • Voltage600
    • Amps100
  9. FAL34100- RECONDITIONED

    FAL34100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG, LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesFAL
    • Phase3
    • Poles3
    • Voltage480
    • Amps100
  10. FAL36100- RECONDITIONED

    FAL36100- RECONDITIONED

    MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 480 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ, 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC, 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 14 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 415 VAC (IEC); 10 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG, LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H; APPROVAL UL, CSA, CE; FA MODEL; APPLICABLE STANDARD W-C-375B/GEN *NOT A LICENSED SQUARE D DISTRIBUTOR *SURPLUS OR RECONDITIONED PRODUCTS SUBJECT TO BD ELECTRICAL'S 2 YEAR WARRANTY *IMAGE IS FOR REPRESENTATION PURPOSES ONLY
    • ManufacturerSquare D Company
    • SeriesFAL
    • Phase3
    • Poles3
    • Voltage600
    • Amps100